Roofing Materials / TPO / Fleece-Backed
EZ TPO Fleece-Backed Membrane
Fleece-Backed TPO is internally reinforced with a weft-inserted polyester scrim and externally with an 8 oz, 55 mil polyester fleece backing for superior cut and puncture resistance.
System
Colors
White
Overview | Options | Documents | Videos | Accessories
Overview
GenFlex Fleece-Backed TPO membranes deliver the perfect combination of durability, flexibility and adhesion performance. Each membrane is internally reinforced with a weft-inserted polyester scrim and externally backed with an 8 oz polyester fleece for added toughness and puncture resistance. Designed to be fully adhered with GenFlex FB Bonding Adhesive LVOC, this versatile system provides excellent wind uplift performance and enhanced protection across a range of approved substrates. Meeting or exceeding ASTM D6878 standards, GenFlex Fleece-Backed TPO offers long-term reliability and proven performance for today’s demanding roofing environments.
Installation methods
Options
45 mil
60 mil
Documents
Specifications
Guides
Codes
| Title | Link |
|---|---|
| Miami-Dade NOA – GenFlex EZ TPO and GenFlex EZ Fleece Backed TPO Single-Ply Roof Systems over Wood Decks | |
| TDI RC-604 – GenFlex EZ Fleece Backed TPO with SBS Modified Roofing Systems | |
| TDI RC-667 – GenFlex EZ TPO Roofing Systems Installed over Concrete Roof Decks | |
| TDI RC-668 – GenFlex EZ TPO Roofing Systems Installed over Steel Roof Decks | |
| TDI RC-669 – GenFlex EZ TPO Roofing Systems Installed over Gypsum Roof Decks | |
| TPO-1-120-114-@-6OC | |
| TPO-1-120-114-@-6OC | |
| TPO-1-60-114-@-12OC | |
| TPO-1-60-114-@-12OC | |
| TPO-1-60-114-@-6OC | |
| TPO-1-60-114-@-6OC | |
| TPO-1-60-142-@-6OC | |
| TPO-1-60-142-@-6OC | |
| TPO-1-60-72-@-18OC | |
| TPO-1-60-72-@-18OC | |
| TPO-1-60-90-@-12OC-WIDE-WELD | |
| TPO-1-60-90-@-12OC-WIDE-WELD | |
| TPO-1-75-90-@-12OC | |
| TPO-1-75-90-@-12OC | |
| TPO-1-75-90-@-6OC | |
| TPO-1-75-90-@-6OC | |
| TPO-1-90-114-@-6OC | |
| TPO-1-90-114-@-6OC | |
| TPO-1-90-72-@-12OC-WIDE-WELD | |
| TPO-1-90-72-@-12OC-WIDE-WELD | |
| TPO-1-90-72-@-6OC | |
| TPO-1-90-72-@-6OC |
Details
Base Tie-In
| Title | File Type | Link |
|---|---|---|
| EZT-FB-BT-01 | dwg | |
| EZT-FB-BT-01 BASE TIE-IN WITH STANDARD EZ TPO MEMBRANE FLASHING AND SEAM PLATES FASTENED TO DECK | ||
| EZT-FB-BT-02 | dwg | |
| EZT-FB-BT-02 BASE TIE-IN WITH SEAM PLATES FASTENED TO WALL OR CURB | ||
| EZT-FB-BT-03 | dwg | |
| EZT-FB-BT-03 BASE TIE-IN AT CURB – PARAPET WITH EXISTING CANT | ||
| EZT-FB-BT-04 | dwg | |
| EZT-FB-BT-04 TIE-IN AT SHINGLES | ||
| EZT-FB-BT-05 | dwg | |
| EZT-FB-BT-05 BASE-TIE IN WITH EZ TPO COATED METAL WITH BRAKE | ||
| EZT-FB-BT-06 | dwg | |
| EZT-FB-BT-06 BASE TIE-IN WITH EZ TPO COATED METAL WITH BRAKE SPLICE | ||
| EZT-FB-BT-07 | dwg | |
| EZT-FB-BT-07 BASE TIE-IN WITH EZ TPO COATED METAL WITHOUT BRAKE | ||
| EZT-FB-BT-08 | dwg | |
| EZT-FB-BT-08 BASE TIE-IN WITH EZ TPO COATED METAL WITHOUT BRAKE SPLICE | ||
| EZT-FB-BT-09 | dwg | |
| EZT-FB-BT-09 MEMBRANE SECUREMENT AT OUTSIDE CORNER | ||
| EZT-FB-BT-10 | dwg | |
| EZT-FB-BT-10 MEMBRANE SECUREMENT AT INSIDE CORNER | ||
| EZT-FB-BT-12 | dwg | |
| EZT-FB-BT-12 BASE TIE-IN WITH FOAM ADHESIVE AND SEPARATE EZ TPO FLASHING | ||
| EZT-FB-BT-13 | dwg | |
| EZT-FB-BT-13 BASE TIE-IN WITH SEAM PLATE INTO DECK WITH DECK OBSTRUCTION | ||
| EZT-FB-D-01 | dwg | |
| EZT-FB-D-01 ROOF DRAIN TARGET PATCH REQUIRED EZ FLEECE BACKED TPO ADHERED SYSTEM | ||
| EZT-FB-D-02 | dwg | |
| EZT-FB-D-02 ROOF DRAIN TARGET PATCH REQUIRED EZ FLEECE BACKED TPO MECHANICALLY ATTACHED SYSTEM |
Corner
Drain & Scupper
Lap Splice
| Title | File Type | Link |
|---|---|---|
| EZT-FB-LS-01 | ||
| EZT-FB-LS-01 EZ FLEECE BACKED TPO MEMBRANE LAP SPLICE WITH CONTINUOUS WELD WITH SELVEDGE EDGE | dwg | |
| EZT-FB-LS-02 | dwg | |
| EZT-FB-LS-02 EZ FLEECE BACK TPO MEMBRANE SPLICE EZ FLEECE BACK TPO MEMBRANE SPLICE | ||
| EZT-FB-LS-03 | dwg | |
| EZT-FB-LS-03 LAP SPLICE WITH MECHANICAL ATTACHMENT | ||
| EZT-FB-LS-04 | dwg | |
| EZT-FB-LS-04 EZ FLEECE BACKED TPO MEMBRANE END LAP SPLICE OVER FIELD SEAM | ||
| EZT-FB-LS-05 | dwg | |
| EZT-FB-LS-05 LAP SPLICE WITH HEADLAP UNDER FIELD SEAM USING T-JOINT COVER | ||
| EZT-FB-LS-06 | dwg | |
| EZT-FB-LS-06 LAP SPLICEWITH HEADLAP OVER FIELD SEAM USING T-JOINT COVER | ||
| EZT-FB-LS-07 | dwg | |
| EZT-FB-LS-07 LAP SPLICE – MECHANICALLY ATTACHED FLEECE BACKED MEMBRANE HAIL WARRANTY REQUIREMENT |
Penetration
Roof Edge
| Title | File Type | Link |
|---|---|---|
| EZT-FB-RE-01 | dwg | |
| EZT-FB-RE-01 FLEECE BACKED TPO MEMBRANE ROOF EDGE WITH SNAP-ON FASCIA AND EXTRUDED CLEAT | ||
| EZT-FB-RE-02 | dwg | |
| EZT-FB-RE-02 FLEECE BACKED TPO MEMBRANE ROOF EDGE WITH CANTED METAL ROOF EDGE AND CRIMP ON FASCIA | ||
| EZT-FB-RE-03 | dwg | |
| EZT-FB-RE-03 FLEECE BACKED TPO MEMBRANE ROOF EDGE GUTTER WITH METAL DRAIN BAR | ||
| EZT-FB-RE-04 | dwg | |
| EZT-FB-RE-04 FLEECE BACKED TPO MEMBRANE ROOF EDGE WITH FASCIA METAL BY OTHERS | ||
| EZT-FB-RE-05 | dwg | |
| EZT-FB-RE-05 ROOF EDGE WITH EZ TPO COATED WITH EZ FB TPO MEMBRANE SELVEDGE EDGE | ||
| EZT-FB-RE-05A | dwg | |
| EZT-FB-RE-05A ROOF EDGE WITH EZ TPO COATED METAL WITH EZ FB TPO MEMBRANE SELVEDGE EDGE AT SPLICE INSTALLATION STEPS 1 & 2 | ||
| EZT-FB-RE-05B | dwg | |
| EZT-FB-RE-05B ROOF EDGE WITH EZ TPO COATED METAL WITH EZ FB TPO MEMBRANE SELVEDGE EDGE AT SPLICE INSTALLATION STEPS 3 & 4 | ||
| EZT-RE-02 | dwg | |
| EZT-RE-02 EZ FLEECE BACKED TPO MEMBRANE ROOF EDGE WITH SNAP ON FASCIA AND EXTRUDED CLEAT – PEAL & STICK |
Termination
Safety Data Sheets
*See the SDS Portal for additional languages.
